| Pipe Dimension (mm) |
Pipe Weight (Tonne) |
Steel Collar Dimension (mm) |
Maximum Allowable Jacking Force On The Pipe (Tonne) |
| NOM DIA |
EXT DIA |
Internal Diameter |
Wall Thickness |
Overall Length |
S |
W |
Dc |
X |
| Class Z |
Class 1.5Z |
Class 2Z |
Class Z |
Class 1.5Z |
Class 2Z |
Class Z |
Class 1.5Z |
Class 2Z |
Class Z |
Class 1.5Z |
Class Z |
Class 1.5Z |
Class 2Z |
| 375 |
533 |
- |
385 |
375 |
- |
74.0 |
79.0 |
3050 |
- |
0.86 |
0.91 |
4.5 |
200 |
522 |
- |
58.5 |
- |
86 |
86 |
| 450 |
533 |
410 |
- |
- |
61.5 |
- |
- |
3050 |
0.71 |
- |
- |
4.5 |
200 |
522 |
46.0 |
- |
65 |
- |
- |
| 610 |
- |
460 |
450 |
- |
75.0 |
80.0 |
3050 |
- |
1.02 |
1.08 |
4.5 |
200 |
599 |
- |
59.5 |
- |
102 |
102 |
| 600 |
699 |
570 |
- |
- |
64.5 |
- |
- |
3050 |
1.00 |
- |
- |
4.5 |
200 |
688 |
49.0 |
- |
96 |
- |
- |
| 775 |
- |
610 |
600 |
- |
82.5 |
87.5 |
3050 |
- |
1.44 |
1.53 |
4.5 |
300 |
764 |
- |
67.0 |
- |
152 |
152 |
| 750 |
864 |
710 |
- |
- |
77.0 |
- |
- |
3050 |
1.51 |
- |
- |
4.5 |
300 |
853 |
61.5 |
- |
156 |
- |
- |
| 1016 |
- |
760 |
750 |
- |
128.0 |
133.0 |
3050 |
- |
2.81 |
2.91 |
4.5 |
300 |
1005 |
- |
112.5 |
- |
350 |
350 |
| 900 |
1016 |
860 |
- |
- |
78.0 |
- |
- |
3050 |
1.84 |
- |
- |
4.5 |
300 |
1005 |
62.5 |
- |
190 |
- |
- |
| 1194 |
- |
910 |
900 |
- |
142.0 |
147.0 |
3050 |
- |
3.69 |
3.81 |
6 |
300 |
1183 |
- |
126.5 |
- |
471 |
471 |
| 1050 |
1194 |
1010 |
- |
- |
92.0 |
- |
- |
3050 |
2.56 |
- |
- |
6 |
300 |
1183 |
76.5 |
- |
283 |
- |
- |
| 1346 |
- |
1060 |
1050 |
- |
143.0 |
148.0 |
3050 |
- |
4.26 |
4.40 |
6 |
300 |
1335 |
- |
127.5 |
- |
543 |
543 |
| 1200 |
1346 |
1150 |
- |
- |
98.0 |
- |
- |
3050 |
3.06 |
- |
- |
6 |
300 |
1335 |
82.5 |
- |
349 |
- |
- |
| 1511 |
- |
1210 |
1200 |
- |
150.5 |
155.5 |
3050 |
- |
5.06 |
5.22 |
6 |
300 |
1497 |
- |
133.5 |
- |
626 |
626 |
| 1350 |
1511 |
1300 |
- |
- |
105.5 |
- |
- |
3050 |
3.72 |
- |
- |
6 |
300 |
1497 |
88.5 |
- |
405 |
- |
- |
| 1676 |
- |
1370 |
1355 |
- |
153.0 |
160.5 |
3050 |
- |
5.78 |
6.05 |
6 |
300 |
1662 |
- |
136.0 |
- |
715 |
715 |
| 1500 |
1676 |
1450 |
- |
- |
113.0 |
- |
- |
3050 |
4.43 |
- |
- |
6 |
300 |
1662 |
96.0 |
- |
495 |
- |
- |
| 1854 |
- |
1520 |
1505 |
- |
167.0 |
174.5 |
3050 |
- |
6.99 |
7.28 |
6 |
300 |
1840 |
- |
150.0 |
- |
883 |
883 |
| 1650 |
1854 |
1615 |
- |
- |
119.5 |
- |
- |
3050 |
5.21 |
- |
- |
6 |
300 |
1840 |
102.5 |
- |
593 |
- |
- |
| 2032 |
- |
1670 |
1655 |
- |
181.0 |
188.5 |
3050 |
- |
8.30 |
8.63 |
6 |
300 |
2018 |
- |
164.0 |
- |
1069 |
1069 |
| 1800 |
2032 |
1750 |
- |
- |
141.0 |
- |
- |
3050 |
6.68 |
- |
- |
6 |
300 |
2018 |
124.0 |
- |
803 |
- |
- |
| 2210 |
- |
1820 |
1805 |
- |
195.0 |
202.5 |
3050 |
- |
9.75 |
10.09 |
6 |
300 |
2196 |
- |
178.0 |
- |
1272 |
1272 |
| 1950 |
2210 |
1900 |
- |
- |
155.0 |
- |
- |
3050 |
7.99 |
- |
- |
6 |
300 |
2196 |
138.0 |
- |
983 |
- |
- |
Notes:
- Two rubber seals per pipe (i.e. 2 seals per joint) to be used in pipe jointing
- Internal lubrication of steel collar is recommended to facilitate installation of the joint
- Special features on pipe may be incorporated if required by client
- 2 grounting holes for jacking pipes of diameter 900mm and above will be provided located at 1/4 length from each and of pipe, diagonally to each other
- Hume is also able to manufacture pipes of other load capacities from different specifications
|
|
| |
| |
DRAINAGES |Page 1 | Page 2 | Page 3 | Page 4 | Page 5 | Page 6 | Page 7 |
Page 8 | Page 9 | Page 10 | Page 11 | Page 12 | Page 13 | Page 14 |
| |
|
| Top |
 |
HUME CONCRETE MARKETING SDN BHD (8411-T)
Level 2, Bangunan Pan Global,
No. 1A, Jalan Tandang,
P.O.Box 21, 46700
Petaling Jaya, Selangor.
Hot-line: (603) 7785 5282
Tel: (603) 7783 3068
Fax: (603) 7785 1823
E-mail: Adam Hussein (HIMB-PJ) |
 |
|
|
|
|